SGS U.S. TESTING COMPANY INC.
CLIENT:
Advanced Basement Products
7017 Americana Parkway
Reynoldsburg, OH 43068

Test Report No:       574488-R Date:       May 15, 2006

SUBJECT: Resistance to Growth of Mold on the Surface of Interior Coatings in an Environmental Chamber.
SAMPLE ID:Samples identified by the client as “6mm Enduro Board” were received on 1/25/06 in good condition.
TEST REQUESTED: The samples were tested in accordance with ASTM D3273-00. No revisions to this report will be allowed after 90 days of the report date.
TEST DATE: 04/18/06.
RESULTS: Results can be found on the following pages.
CERTIFICATION: The tests reported here were conducted under the continuous direct supervision of SGS U.S. Testing Company Inc., Tulsa, OK.
SIGNED FOR AND ON BEHALF OF
SGS U.S. TESTING COMPANY INC.
S. Scott Parkhurst
Hydro Mechanical Laboratory Manager
Jerry Murray
Hydro Mechanical Laboratory Supervisor

This report is issued by SGS U.S. Testing Company Inc. under its General Conditions for Testing Services, as printed on reverse side. SGS U.S. Testing’s responsibility under this report is limited to proven negligence and will in no case be more than the amount of the testing fees. Except by special arrangement, samples are not retained by SGS U.S. Testing for more than 30 days. The results shown on this test report refer only to the sample(s) tested unless otherwise stated, under the conditions agreed upon. Anyone relying on this report should understand all of the details of the engagement. Neither the name, seals, marks nor insignia of SGS U.S. Testing may be used in any advertising or promotional materials without the prior written approval of SGS U.S. Testing. The test report cannot be reproduced, except in full, without prior written permission of SGS U.S. Testing Company Inc.

Test Procedure and Results


Procedure:
Sample Pre-Conditioning:4 days at 73.5+/-3.5,sup>oF and 50% RH
Environmental Conditions: 90+/-2oF and 97% Humidity
Exposure Time:4 weeks
Cultures:Aureobasidium pullulans, ATCC 9348
Aspergillus Niger, ATCC 6275
Penicillium, ATCC 9849
Soil:25% Peat Moss, PH Level 6.8
Control Samples:Ponderosa Pine Sapwood Panels
Gypsum Board Panels
Ratings:10 = No Growth
0 = Sample Completely Covered
All ratings are based on ASTM D 3273 50 and 100 magnification photographic standards. The ratings determine amount of discoloration on a sample due to the presence of mold.

SAMPLE ID: "6mm Enduro Board"

Face Side Ratings:
 Sample
Week123
1101010
2101010
391010
481010


Back Side Ratings:
 Sample
Week123
110109
2998
3999
4898


*Product Average Rating: 9.291667

******
End of Report


Technical Materials Overview
Material Safety Data SheetFire Rating-1Fire Rating-2Foamed PlasticMold Resistance

Introduction Product Overview Consumer Guide Finished Basement Gallery



Home | About Us | Contact Us | Products | Contractors
The Basement Tuxedo
Introduction | Product Overview | Consumer Guide | Finished Basement Gallery
Dealer Login | Link to Us
This website is valid HTML 4.01 Transitional in compliance with W3C
Problems with this website?
webmaster@advancedbasementproducts.com
Bay State Internet Services